Your browser doesn't support javascript.
loading
Impact of mechanical power and positive end expiratory pressure on central vs. mixed oxygen and carbon dioxide related variables in a population of female piglets.
Fioccola, Antonio; Pozzi, Tommaso; Fratti, Isabella; Nicolardi, Rosmery Valentina; Romitti, Federica; Busana, Mattia; Collino, Francesca; Camporota, Luigi; Meissner, Konrad; Moerer, Onnen; Gattinoni, Luciano.
Affiliation
  • Fioccola A; Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
  • Pozzi T; Department of Health Sciences, Section of Anaesthesiology, Intensive Care and Pain Medicine, University of Florence, Florence, Italy.
  • Fratti I; Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
  • Nicolardi RV; Department of Health Sciences, University of Milan, Milan, Italy.
  • Romitti F; Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
  • Busana M; Department of Health Sciences, University of Milan, Milan, Italy.
  • Collino F; Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
  • Camporota L; IRCCS San Raffaele Scientific Institute, Milan, Italy.
  • Meissner K; Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
  • Moerer O; Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
  • Gattinoni L; Department of Surgical Sciences, University of Turin, Turin, Italy.
Physiol Rep ; 12(4): e15954, 2024 Feb.
Article in En | MEDLINE | ID: mdl-38366303
ABSTRACT

INTRODUCTION:

The use of the pulmonary artery catheter has decreased overtime; central venous blood gases are generally used in place of mixed venous samples. We want to evaluate the accuracy of oxygen and carbon dioxide related parameters from a central versus a mixed venous sample, and whether this difference is influenced by mechanical ventilation. MATERIALS AND

METHODS:

We analyzed 78 healthy female piglets ventilated with different mechanical power.

RESULTS:

There was a significant difference in oxygen-derived parameters between samples taken from the central venous and mixed venous blood (S v ¯ $$ \overline{v} $$ O2 = 74.6%, ScvO2 = 83%, p < 0.0001). Conversely, CO2-related parameters were similar, with strong correlation. Ventilation with higher mechanical power and PEEP increased the difference between oxygen saturations, (Δ[ScvO2-S v ¯ $$ \overline{v} $$ O2 ] = 7.22% vs. 10.0% respectively in the low and high MP groups, p = 0.020); carbon dioxide-related parameters remained unchanged (p = 0.344).

CONCLUSIONS:

The venous oxygen saturation (central or mixed) may be influenced by the effects of mechanical ventilation. Therefore, central venous data should be interpreted with more caution when using higher mechanical power. On the contrary, carbon dioxide-derived parameters are more stable and similar between the two sampling sites, independently of mechanical power or positive end expiratory pressures.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Oxygen / Carbon Dioxide Limits: Animals Language: En Journal: Physiol Rep Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Oxygen / Carbon Dioxide Limits: Animals Language: En Journal: Physiol Rep Year: 2024 Document type: Article Affiliation country: Country of publication: